资料介绍
天线标准
Antenna Performance Standard
1 OTA 3D Performance
The OTA 3D Performance test result is generally considered as the most
important TX &
RX characteristic for mobile devices. Thus any antenna without TRP&TIS test
report
shall not be accepted.
Antenna vendor without 3D chamber must test the TX&RX from different
positions & angles as many as possible in order to simulate TRP&TIS by
linear calculation.
By the suggestion of CTIA, at least 6 theta-cuts must be tested (T0,
T30…T150). Each
theta test data contains 4 phi-cuts (0, 90, 180, and 270).
1.1 TRP
1.1.1 TRP value
The Total Radiated Power emitted by MS shall be no less than the levels in
table1.1 under max Power Control Level.
Table 1.1
|Frequency band |TRP average Value in dBm|
|GSM900 |27