资料介绍
infineon MOSFETS开关电阻电容电感设计指导 Application Note, V 1.1, May 2001
ANPS061E
Guideline for determining
switching losses associated
with switching resistive,
capacitive and inductive
loads.
by Christian Arndt and Michael Mueller-Heiss
Automotive Power
Never stop thinking.
-1-
ANPS061E
Guideline for determining switching losses
1. Abstract 3. General
This Application Note is intended to provide help If a load is switched in a DC application, the
in all cases where FET switching losses due to