首页|嵌入式系统|显示技术|模拟IC/电源|元件与制造|其他IC/制程|消费类电子|无线/通信|汽车电子|工业控制|医疗电子|测试测量
首页 > 分享下载 > 嵌入式系统 > 【应用手册】Cyclone III Configuration Interface Guidelines with EPCS Devices

【应用手册】Cyclone III Configuration Interface Guidelines with EPCS Devices

资料介绍
【应用手册】Cyclone III Configuration Interface Guidelines with EPCS Devices
This application note describes the methods to interface a Cyclone III®
device to a serial configuration device (EPCS) using Cyclone III I/O
voltages of 3.0 V and 2.5 V, in addition to the standard 3.3 V. This
application note discusses the electrical specifications, timing
requirements, signal integrity analysis, and board physical design
guidelines for the supported active serial (AS) configuration schemes.
On Cyclone III devices, bank 1 is used for AS configuration signals and
for user I/Os. The I/O voltage for Cyclone III AS configuration signals
must be compatible with the operating voltage of Altera EPCS devices
and must not conflict with the intended I/O voltages for other bank 1
signals. The Altera EPCS devices support supply voltage from 2.7 V to
3.6 V, which enables it to be operated at 3.3 V or 3.0 V. This application
note shows the methods to use the Cyclone III bank 1 I/O voltages of
3.0 V and 2.5 V with the EPCS device.
Additionally, at any of the Cyclone III I/O voltages of 3.3/3.0/2.5 V, this
application note shows how to create a robust electrical and physical
board design to interface with an EPCS device using single and multidevice
AS configuration. You can create your design based on the signal
integrity analysis and physical design constraints in this application note
to achieve a successful AS configuration.
Cyclone III Configuration
Interface Guidelines with
EPCS Devices
June 2008, version 1.0 Application Note 523



Introduction This application note describes the methods to interface a Cyclone III
device to a serial configuration device (EPCS) using Cyclone III I/O
voltages of 3.0 V and 2.5 V, in addition to the standard 3.3 V. This
application note discusses the electrical specifications, timing
requirements, signal integrity analysis, and board physical desi
标签:AlteraFPGACycloneIIIEPCS
【应用手册】Cyclone III Configuration Interface Guidelines with EPCS Devices
本地下载