high resolution signal confition adcsSECTION 3 HIGH RESOLUTION SIGNAL CONDITIONING ADCs
Sigma-Delta ADCs High Resolution, Low Frequency Measurement ADCs

1

SECTION 3 HIGH RESOLUTION SIGNAL CONDITIONING ADCs Walt Kester, James Bryant, Joe Buxton
The trend in ADCs and DACs is toward higher speeds and higher resolutions at reduced power levels. Modern data converters generally operate on ±5V (dual supply) or +5V (single supply). There are now a few converters which operate on a single +3V supply. This trend has created a number of design and applications problems which were much less important in earlier data converters, where ±15V supplies were the standard. Lower supply voltages imply smaller input voltage ranges, and hence more susceptibility to noise from all potential sources: power supplies, references, digital signals,